Air mattress Axtair Automorpho® Axensor technology: a new communicating and entirely automatic motorised air device generation. Product open to information and communication technologies (ICTs). Extensive traceability will make it easier for users to manage their stock of mattresses more effectively.
- Axensor® technology combining the functions regarding detection of chest rest tilting, transmission towards the compressor, analysis and communication by Bluetooth of technical and usage data of the device
- Traceability of technical events and events linked to usage of the medical device. Assistance with preventive and curative maintenance
- Help with treating installed bedsores by a clinically tried and tested alternating principle (EC2005-06, EC2007-8, EC2013)
- Patient weight: 200 Kg
- Heel supports
Helps preventing pressure ulcers for patient at high risk of pressure ulcer development, bedridden more than 15 hours a day. Also helps treating existing pressure ulcers from stage 1 to 4 in areas at risk.
- 30 TO 200 KG/4.7 TO 31.4 ST
- 20 cm therapeutic air cells
4 therapeutic zones:
- 2 static air cells located in head area
- 2 static air cells located in head area
- 4 cervico-dorsal cells
- 10 air cells around the sacrum area with a
static air base to ensure stability and avoid
bottoming out - 5 independent heel relief air cells
Optional supine position
- Selective deflation of air cells to prevent from cutaneous injuries and facilitate bronchial secretions for mechanically ventilated patients
Lateral CPR Valve
- Allows deflating the mattress in less than 15 seconds to proceed with an external cardiac massage
Pump
Patented system of automatic and continuous calculation of inflation pressure according to patient’s morphology and position in bed
- Automatic recognition of the connected pressure care
system - 3 modes: dynamic, static low pressure, care
- Communicating function
- “I” Touch for technical information
- Visual and audible alarms
- Serial number on the pump’s back, simplified
instruction and QR code on both sides. - 22 x 25 x 11.5 cm 3 modes: dynamic, static low pressure and care (for the axensor cushion only dynamic mode is available in connected mode).
- Technology based on alternating pressure 1 cell in 2 over a complete cycle from 14 to 20 minutes Patented system of automatic and continuous calculation of inflationpressure according to patient’s morphology and position.
- Audible and visual alarms.
Flow > 8 l/min. - 220-240 V – 50Hz Class II type BF;
- Average consumption: 5 Watts
- Sound power <35 dBA according to
- NF ISO 3744:1995
- Electric and electromagnetic
- Compliance according to standards